Ebara CDX/I 120/07
CDX-CDXL
Surface
SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS
Single impeller centrifugal electric pumps with hydraulic parts in AISI
304 and AISI 316 stainless steel
APPLICATIONS
Micro Breweries
Domestic pressure boosting
Small-scale garden irrigation
Washing
Treating water
Cooling towers
Moving clean water in general
TECHNICAL DETAILS
Solid hydraulic structure
Small dimensions
PUMP TECHNICAL DATA
Maximum working pressure: 8 bar
Maximum temperature of the liquid:
-5°C ÷ +60°C for CDX(L) 70/05-70/07-90/10
-5°C ÷ +90°C for the rest of CDX(L) range
-5°C ÷ +110°C in the H-HS-HW-HSW-E version
G1½ suction connection for CDX (L) 200, G1¼; for the rest of the range
G1 discharge connection
MEI > 0,4
For further information please see our Data Book
MOTOR TECHNICAL DATA
High efficiency IE2 motors starting from 0,75kW
Self-ventilated 2 pole asynchronous motor
Class of insulation F
IP55 Protection degree
230V ±10%, 50Hz single phase voltage
230/400V ±10%, 50Hz three phase voltage
Permanent capacitor inserted and thermo-amperometric protection
with automatic rearm incorporated for the single phase motor
Protection under user's responsibility for the three phase version
MATERIALS
Version in AISI 304
Pump casing, impeller, diffuser and casing cover in AISI 304
Shaft in AISI 303 (part in contact with the liquid)
Version (L) in AISI 316
Pump casing, impeller, diffuser and casing cover in AISI 316
Shaft in AISI 316 (part in contact with the liquid)
Bracket and motor frame in aluminium
Mechanical seal in:
- Ceramic/Carbon/NBR (standard)
- Ceramic/Carbon/FPM (version H)
- SiC/SiC/FPM (version HS)
- Tungsten Carbide/Tungsten Carbide/FPM (version HW )
- SiC/Tungsten Carbide/FPM (version HSW)
- Ceramic/Graphite/EPDM (version E)
- Tungsten Carbide/Special Carbon/EPDM (version U3CEGG)
The code on my pump is different
The code has changed many times due to motor efficiency regulations, EuP/ErP and there has been harmonisation across Europe also. The base code is the CDX or CDXM denoting three phase and single phase respectfully.
After CDX or CDXM there is another code letter
This code letter after the CDX or CDXM code is for the motor efficiency rating. Around 2013 the codes were /A, /B or /E denoting their IE rating. You can disregard this rating as we will supply the current IE rated motor to meet European legislation. If you would like to know more about the legislation then Google ErP/EuP or contact us and we can provide.
What are the additional codes
The additional code that denotes the seal materials are: H = Viton HS = Silicon with Viton E = EPDM For example CDXHM 70/05 is a CDX pump with single phase and Viton elastomers for up to 110 Deg C, CDXHS 70/05 is a CDX pump with 3 phase and Silicon vs. Silicon with Viton elastomers for 110 Deg C and soft solids
UK Mainland Delivery is normally by next working day courier if order is placed before 1.30pm. ie despatched on Monday for Tuesday delivery. If placed after 1.30pm then the goods will be despatched the next working day. ie Monday for Wednesday delivery. Highlands and offshore deliveries differ.